Half the calibrations
A twelve month interval instead of six. At $180 a calibration that is one visit a year rather than two, and one less date to hold in the service log.
Meridian Pro / bench instrument
Meridian Pro was rebuilt around a reference cell that does not drift. Fourteen months on the bench, drift measured every thirty days, every unit inside tolerance. That is what moved the calibration interval from six months to twelve.
Why sites choose it
None of them is a feature list. They are the things a site notices in the first year of owning one.
A twelve month interval instead of six. At $180 a calibration that is one visit a year rather than two, and one less date to hold in the service log.
An account manager, an operations lead, and a customer success lead, with direct lines. The same three names for the life of the account.
Every figure below is the figure in the certificate that ships with the unit. Nothing is rounded in the direction that flatters it.
Specification
Measured at 23 degrees Celsius after the stated warm-up, against the reference standard the certificate names.
| Measurement range | 0.0001 to 200.0000 units, four channels |
|---|---|
| Resolution | 0.0001 units across the full range |
| Accuracy | Plus or minus 0.05 percent of reading, plus one count |
| Calibration interval | 12 months for serials M7-2026-0400 and above |
| Warm-up | 18 minutes to stated accuracy from a cold start |
| Ports | Four sample ports, one reference port, one auxiliary |
| Data | USB-C and Ethernet, CSV and JSON export, no cloud account required |
| Power | 100 to 240 volts, 50 or 60 hertz, 45 watts typical |
| Dimensions | 340 by 260 by 145 millimetres |
| Weight | 4.8 kilograms |
| Warranty | Three years, parts and labour, extended to five on Atlas Care Plus |
Meridian Bench is $4,850 and Meridian Field Kit is $1,240. Both carry the same certificate format and the same twelve month interval.
From a partner network
We stopped scheduling around calibration and started scheduling around the work.
Service plans
Every plan covers every Meridian model on the site. Plans can be changed at any renewal, and nothing here is locked to a term.
$0 per month
Buy the instrument, call when you need something. Calibration and training are charged at the published rate.
Most sites
$89 per month
The plan for a site that wants the calibration handled and a phone number that is answered.
$149 per month
For a network running several units, where a bench standing idle costs more than the plan.
Questions
Talk to the team
Send the models and serials and you will get a written quote, a turnaround date, and the name of the person who will handle it.
400 Meridian Way, Suite 200
Tampa, FL 33602
This form is a demonstration. It has no action and no endpoint. Nothing you type is sent anywhere, stored, or read by anyone.